Benchtop spectrometer for the analysis of metals and alloys
Iskroline 100 is a cost-effective spark spectrometer with best-in-class price / analytical performance with high quality workmanship and reliability. The device is designed for fast and accurate spectral analysis of metals and alloys with various bases (Fe, Al, Cu, Zn, Pb, Sn, Sb, Ni, Ti, Co, Mg).
The Iskroline 100 benchtop spark spectrometer is a modern express analyzer of the composition of metals and alloys. The operation of the device is based on the method of emission spectral analysis, which uses the dependence of the intensity of spectral lines on the content of an element in a sample.
The main purpose of the device is an accurate and fast analysis of conductive samples with various bases (Fe, Al, Cu, Zn, Pb, Sn, Ni, Ti, Co, Mg, etc.). This spectral analyzer is designed for quantitative analysis of the composition of both non-ferrous metals and ferrous metals (cast irons, low-alloy, medium-alloy, many high-alloy steels, etc.) for most of the known alloying elements and impurities, including sulfur, phosphorus and carbon.
Iskroline 100 - a modern floor-standing emission spectrometer for spectral analysis of metals and alloys The device is capable of solving most analytical problems in heavy industry. In this regard, the scope of Iskroline 100 is very wide:
Pay attention to the features of the spectral analysis of cast irons
This spark spectrometer can be both the only means of non-destructive control of the composition of metals and alloys in small and medium-sized enterprises, and it can work as part of complex production and analytical complexes in laboratories and workshops of large enterprises of ferrous and non-ferrous metallurgy.
Any spectral lines in the range of 167 - 460 nm (including phosphorus, sulfur and carbon lines) with a resolution of 0.02-0.03 nm are available.
The Iskroline 100 is a cost-effective benchtop emission spectrometer with best-in-class price / analytical performance combined with high quality workmanship and reliability. If you need a mobile version of the spectrometer for working in a batch yard or a shop / warehouse for analysis, including large-sized parts, we recommend considering the Iskroline 500 mobile spectrometer model with an external probe. You can check the prices and features of these spectrometers in the configuration you are interested in with our specialists.
The Iskroline 100 emission spectrometer is included in the State Register of Measuring Instruments in Russia, Belarus, Kazakhstan, etc. The device meets the safety requirements for electrical equipment and electromagnetic compatibility (GOST R 52319-2005, GOST R 51522.1-2011).
Iskroline 100 consists of a spectral excitation system based on a SPARKS LCR-discharge generator, a 1S2133 vacuum spectrograph, a registration system on 9 linear CCD detectors, systems: control, gas supply, evacuation, and a housing.
Concentration measurement range,% | from 0.0001 to tens * | |||
Relative random error (depending on the element, the value of the mass fraction and the quality of GSO),% | less than 0.5 – 40 | |||
Spectrum excitation source | Discharge type | low voltage unipolar spark in argon atmosphere | ||
Voltage, V | 200 – 500 | |||
frequency Hz | 100; 200; 300; 400 | |||
Capacitance, μF | 2.2; 4.4; | |||
Inductance, μH | 40, 270, 750, 2400 (on request) | |||
Resistance, Ohm | 0.3; 0.99; 3.3 | |||
Working spectral range, nm | 167 – 460 | |||
Spectral resolution, nm | 0.02 – 0.03 | |||
Average inverse linear dispersion, nm / mm | 1.25 | |||
Photodetectors (linear CCD detectors TCD1304DG, TOSHIBA), pcs | 9 | |||
Duration of one frame, s | 0.004 – 60 | |||
Number of frames | 1 – 500 | |||
Interface | USB2.0 | |||
Frame transfer mode | все кадры | all shots | ||
average over all frames | there is | |||
Power supply | (220 + 22-33) V, (50 ± 2) Hz | |||
Power consumption, no more, W | no spark | 500 | ||
when a spark is burning | 900 | |||
Weight, no more, kg | 80 |
The detection limit (or detection limit) is one of the metrological characteristics that must be checked during the initial verification of each Iskroline spectrometer.
S | 0,00006 |
P | 0,00002 |
C | 0,00006 |
Si | 0,00007 |
Cu | 0,0001 |
Mg | 0,0001 |
Ti | 0,00006 |
W | 0,0001 |
Nb | 0,00006 |
Ni | 0,0001 |
Cr | 0,000005 |
Al | 0,0003 |
Mo | 0,0002 |
V | 0,00004 |
Pb | 0,0007 |
Sb | 0,000008 |
Ag | 0,00004 |
As | 0,00001 |
Mn | 0,00006 |
** The detection limits were calculated using the "3σ" criterion for Fe, Cu, Al bases and were obtained using real methods under typical analysis conditions. Random errors in determining 100 mass fractions of elements on Iskroline in the GSO sets of carbon and alloy steels UG0d - UG9d and UG75 - UG79 in comparison with the requirements of GOST 18895-97 “Steel. Method of photoelectric spectral analysis ”.